Tecnocreo Engineers Engineering and environment
Environmental modelling in a control room

Calculation tools

We do not buy the models.
We write them.

The Suite Green brings together the Windows programs and web platforms that Tecnocreo has developed through its own research and innovation work and uses every day in its studies and projects: air, noise, vibration, electromagnetic fields, water, energy, monitoring and construction site sustainability.

This is not about saving money. When a contracting authority asks how a figure was obtained, the answer does not stop at the name of a program: we can open up the method, show the assumptions and redo the calculation changing whatever needs changing.

It also means the tools follow the commissions. When a standard changes or an authority asks for a check in a new form, the software adapts on the project’s timescale, not a supplier’s.

Desktop programs
Six
Web platforms
Seven
Use
Internal working tools, not licensed products

> download the Suite Green brochure (PDF)

Areas covered

Air
GreenAirPuff
Noise
GreenNMR · GreenNoise
Vibration
GreenVWave · GreenNMR
Electromagnetic fields
GreenElfWave · GreenHLFWave
Water
GreenRAS · GUI SWMM
Soil and groundwater
ProUCL-MCP
Renewable energy
GreenWind · GreenGlare
Construction sites
GreenGIS · GreenWorks

Windows programs

Six desktop applications

GreenAirPuff

Atmospheric dispersion with CALPUFF 6.42 and generation of CALMET files from public data; verification of the limits of Legislative Decree 155/2010 and of odour.

CALPUFF · D.Lgs. 155/2010

> PDF data sheet

Annual mean NO₂ concentration at ground level: the two emission cores and the concentration isolines
Annual mean NO₂ concentration at ground level: the two emission cores and the concentration isolines

GreenNMR

Processing of noise and vibration measurements and ready-made reports: environmental noise, workers, buildings, building acoustics.

DM 16/03/1998 · D.Lgs. 81/2008

> PDF data sheet

Twelve minutes of measurement: level time history and one-third octave spectrogram
Twelve minutes of measurement: level time history and one-third octave spectrogram

GreenNoise

Outdoor noise propagation with ISO 9613-2 and CNOSSOS-EU: plants, roads, railways, airports; imports GIS, CAD and other project formats.

ISO 9613-2 · CNOSSOS-EU · ECAC Doc 29

> PDF data sheet

Daytime noise map of a construction site: 79,717 calculation nodes, point and line sources
Daytime noise map of a construction site: 79,717 calculation nodes, point and line sources

GreenRAS

HEC-RAS projects: verification, 1D steady flow with its own engine, flood maps, HEC-RAS automation.

HEC-RAS 7.x · FHWA HDS-5

> PDF data sheet

Flooded area at the design profile, derived from the depth model
Flooded area at the design profile, derived from the depth model

GUI SWMM

Italian-language interface for EPA SWMM 5.2: drainage networks, design hyetographs from IDF curves, hydrographs towards GreenRAS.

EPA SWMM 5.2.4

> PDF data sheet

Urban drainage network: conduits coloured by peak flow, flooded node and outfall
Urban drainage network: conduits coloured by peak flow, flooded node and outfall

ProUCL-MCP

Connector to the ProUCL 5.2 engine: UCL95, background values, comparisons and trends on environmental data.

ProUCL 5.2 · SNPA 174/2018

> PDF data sheet

Data distribution, goodness-of-fit tests and the 95% UCL of the mean over 132 measurements
Data distribution, goodness-of-fit tests and the 95% UCL of the mean over 132 measurements

Web platforms

Seven platforms, accessible from the browser

GreenGIS

Environmental Monitoring Plans for construction sites: 12 matrices, thresholds, QA/QC, progress, OGC services and ANAS export.

PMA · INSPIRE · OGC

> PDF data sheet

One year of PM10 at the monitoring points, with the daily limit exceedance
One year of PM10 at the monitoring points, with the daily limit exceedance

GreenElfWave

50 Hz fields and first-approximation distances for lines, cables, substations, railways and HVDC, with verification of protected places and buildings.

DPCM 8/7/2003 · DM 29/5/2008

> PDF data sheet

Double-circuit 380 kV line and its setback corridor: 31 m DPA around the axis
Double-circuit 380 kV line and its setback corridor: 31 m DPA around the axis

GreenHLFWave

RF electromagnetic fields of radio base stations, broadcast, radio links and Wi-Fi, with maps and report.

DPCM 8/7/2003 · L. 214/2023 · CEI 211-10

> PDF data sheet

Electric field around a three-sector radio base station, with the compliance isolines
Electric field around a three-sector radio base station, with the compliance isolines

GreenVWave

3D propagation of ground-borne vibration from construction sites and infrastructure, with checks at the receivers and figures for the report.

UNI 9614 · ISO 8041

> PDF data sheet

Ground vibration map, in dB re 1 µm/s², with amplitude isolines
Ground vibration map, in dB re 1 µm/s², with amplitude isolines

GreenGlare

Glare from photovoltaic plants with the SGHAT method, FAA outcomes, ENAC screening and parametric study.

SGHAT · FAA · ENAC

> PDF data sheet

Glare hazard: 3,572 glare points on the Ho zones
Glare hazard: 3,572 glare points on the Ho zones

GreenWind

Wind farms: P50/P90 energy yield with terrain and wake effects, 5D × 3D spacing and three-level throw distance.

D.M. 10/09/2010

> PDF data sheet

Wind rose over twenty years of records, by sector and speed class
Wind rose over twenty years of records, by sector and speed class

GreenWorks

Construction site sustainability under UNI/PdR 172:2025: 32 indicators, the Chessboard Rule, class and dossier.

UNI/PdR 172:2025

> PDF data sheet

Relevance of the UNI/PdR 172:2025 indicators and sustainability class of the site
Relevance of the UNI/PdR 172:2025 indicators and sustainability class of the site

Research

From funded research to everyday tools

Some of these applications come out of the research and development projects we take part in: AR.SMARTFLOW on augmented reality applied to design, MARBLE-UP on the circular economy of materials, MARECO on the recovery of marine resources.

> the research projects

Contact

Have a specialist calculation to set up?

Via Girolamo Savonarola, 15
54033 Marina di Carrara (MS), Italy

info@tecnocreo.it
+39 0585 876887