Tecnocreo Engineers Engineering and environment
Reinforced concrete frames during seismic upgrading

Structural detailed design

Auditorium in the former fruit and vegetable market area of Arezzo

Seismic upgrading of a 1960s reinforced concrete frame building to become a public auditorium.

The building has a trestle-type structure with thirteen main reinforced concrete frames of beams and columns of variable section, AQ42 plain steel reinforcement and isolated pad foundations. Checks on the existing condition found that the ridge beam and main girders failed static verification, with widespread seismic deficiencies due to one-way frames and low reinforcement ratios.

The design fully demolishes the roof slabs and the tie beams of the thirteen portals in alternate bays, keeping only the main frame; builds a raft and foundation beams in two portions together with the service routes; and inserts a new steel support cage with columns, beams and bracing in the vertical plane and in the roof.

The geotechnical campaign of December 2024, with six tromometric measurements and a down-hole test, placed the seismic bedrock at about 100 m depth, classifying the ground as category C. The cost plan for this phase shows €1,368,492 of works and €22,269 of safety costs.

Auditorium construction site with concrete structure and steel roof

Project data

Sector
Building
Year
2025
Tecnocreo's role
Designers

> back to projects

Services delivered

Detailed design
Geotechnical report
Structural report and calculations
DNSH and CAM report
Safety and coordination plan
Bill of quantities and cost plan

Other projects

> all projects

Contact

Have a project to set up?

Via Girolamo Savonarola, 15
54033 Marina di Carrara (MS), Italy

info@tecnocreo.it