In-situ tests to UNI EN 1793-5
In-situ verification of the acoustic performance of noise barriers installed along the national motorway network, using the Adrienne method.
The assignment is part of a framework agreement for the in-situ verification of the acoustic performance of road traffic noise reducing devices. The lot awarded covers the north-western area of the network, for a total value of €3,012,541.77.
Measurements follow the Adrienne method of UNI EN 1793-5:2016: with a source and a microphone array placed in front of the panel, the impulse response is used to separate the direct, reflected and transmitted contributions. From these the reflection index and the airborne sound insulation index are derived in one-third octave bands and compared with the values declared by the manufacturer.
One example of the campaigns carried out is the test on a 3.5 m high metal barrier with posts at 2.10 m centres, measured on the motorway in December 2025. Tecnocreo operates as an ISO/IEC 17025:2017 accredited laboratory, in a temporary consortium with other qualified companies.